Features:
Specifications:
Specifications | Range | Resolution | Accuracy | |
AC Voltage | 80V/180V/400V/600V | 0.1V/0.1V/1V/1V | (1.0%+5) | |
AC Current | 20A/40A/100A/200A/ 450A/1000A | 0.01A/0.01A/0.1A/0.1A/ 1A/1A | (2.0%+5) | |
Active Power | 30kW/60kW/120kW | 0.01kW/0.01kW/0.1kW | (3.0%+5) | |
150kW/300kW/600kW | 0.1kW | (3.0%+5) | ||
Apparent Power | 3kVA/12kVA/30kVA | 0.001kVA/0.01kVA/0.01kVA | (3.0%+5) | |
120kVA/150KVA/600kVA | 0.1kVA | (3.0%+5) | ||
Reactive Power | 3kVAr/12kVAr/30kVAr | 0.001kVAr/0.01kVAr/0.01kVAr | (3.0%+5) | |
120kVAr/150KVAr/600kVAr | 0.1kVAr | (3.0%+5) | ||
Power Factor | 0.3~1 | 0.001 | (2.0%+2) | |
Frequency | 30Hz~1000Hz | 0.1Hz | (0.5%+1) | |
Harmonic Measurement 45Hz~65Hz (fundamental) | Harmonic Number :1 | (3.0%+10) | ||
Harmonic Number :2-6 | (3.5%+10) | |||
Harmonic Number :7-8 | (4.5%+10) | |||
Harmonic Number :9-10 | (5.0%+10) | |||
Harmonic Number :11-15 | (7.0%+10) | |||
Harmonic Number :16-20 | (10%+10) |