Weighing Transmitter Weighing Amplifier Weight Sensor Voltage Current Converter DC 12-24V 4-20MA Loa

New
-+
12 available
R637.00
Shipping
Standard courier shipping from R30
R30 Standard shipping using one of our trusted couriers applies to most areas in South Africa. Some areas may attract a R30 surcharge. This will be calculated at checkout if applicable.
Check my rate
Ready to ship in
The seller has indicated that they will usually have this item ready to ship within 15 business days. Shipping time depends on your delivery address. The most accurate delivery time will be calculated at checkout, but in general, the following shipping times apply:
 
Standard Delivery
Main centres:  1-3 business days
Regional areas: 3-4 business days
Remote areas: 3-5 business days
Buyer Protection How you're covered
Get it now, pay later
Returns
Replacement 7 Days
Replacement Guarantee: 7 Days: We stand by this guarantee

Product information

Condition:
New
Location:
International
Bob Shop ID:
612373764
.size_table_start table,.size_table_start table tr td { border:2px solid #ddd;}.size_table_start table { width: 100%; min-height: 25px; line-height: 25px; text-align: center; border-collapse: collapse;}.size_table_start,.size_table_end {clear:both;}
Description: ? Housing and wire connectors are waterproof design, good sealing, suitable for harsh environments Look beautiful, durable, anti-jamming performance Ultra- high-precision op-amp circuit, high accuracy, good stability The power supply has reverse polarity protection, surge protection, overcurrent protection Suitable for weighing, pull pressure, torque, and other strain sensors.
Technical Parameters:? ? Working voltage: DC 12-24V Output signal: voltage (0-5V, 0-10V, 1-5V, ± 5V) 4-20ma input signal: sensor sensitivity 2.0MV/V output incentive: 5V(E+) Operating temperature range: -20 - 80?ᆪC Operating Humidity: 10% RH-90% RH (non-condensing) Accuracy: better than 0.1% F.S Precision: better than 0.05% F.S Gear selection: dial switch turn OFF, V0 output 0-5v, 1 turn to ON V0 output 0-10V, 1 and 2 both turn to OFF, VO output 0-5v, IO output 4-20MA .
About debugging: ? 1 zero adjustment First of all, make the system is in the idle state, adjust the marking ZERO potentiometer to adjust the zero offset. The multimeter is used to measure the output voltage or current, let show value as close as possible to the zero value display. Or change the magnification zero change will become big. 2 gain adjustment The system loading a certain weight value (the recommended range: 80% ~ 100% FS), the calculation of the output current value according to the load weight and the maximum weighting value relation, using the digital multimeter monitoring output, potentiometer to adjust amplifier gain spin-labeled SPAN. 3 the retest The system is in the idle state, measuring the zero output; loading a certain weight value, output voltage measurement whether fluoride expectation magnification If not, repeat steps 1, 2 adjust again.
Package includes:? ? 1 x Load Cell sensor Amplifier Transmitter?



More from this seller

View all
R30 shipping
10pcs Wave Pattern Mop Cloth for Ecovacs Deebot X1 Omni Turbo Robot
R495
R30 shipping
Copper Infused Knee Support Brace Patella Arthritis Leg Support Joint Compression Sl... (SIZE 3: XL)
R414
R30 shipping
500mm Length 4040 T Slot Aluminum Profiles Extrusion Frame For CNC
R657
R30 shipping
Wine Glass Rack Holder Storage Metal ,punch Free Hanging Set Of 2
R374
Add to cart

Similar products

R30 shipping
AD Weighing Sensor Module Dual-channel 24-bit A/D Conversion HX711 Shieding
R357
R30 shipping
DC 9-36V to 12V 1A 2A 3A DC DC Converter 12V DC Voltage Converter Step Down Buck C... (CURRENT: 3A)
R556
R30 shipping
HX711 DC 3.3V 5V 4Bit Pressure Sensor Weighing Electronic Scale Module Red Digital Tube Display Scre
R335
R30 shipping
5pcs DD40AJSA 5-40V to 24V 12V 5V Wide Voltage Adjustable Step Down DC Voltage Converter Power Regul
R526