This item has closed with no items sold
View the relisted Item
View other items offered by szulou3886

Similar products

33% OFF
SINOTIMER DDS6619 80A 230V Din Rail Single Phase Energy Meter Voltage Current Power Meter With Back
New
R307.00 R461.00
Digital DC 0-100V 0-10A 250W Tester DC7-12V LCD Digital Display Voltage Current Power Meter Voltmete
New
R372.00
DC 100V 10A Mini Digital Voltmeter Ammeter Voltage Current Meter Tester With Blue /... (COLOR.: RED)
New
R398.00
3Pcs M4430 Mini Digital Voltmeter Ammeter DC 200V 10A Panel Amp Volt Voltage Current Meter Tester De
New
R496.00
100A /200A /300A/500A LCD Combo Meter Voltage Current KWh Watt Meter 12V 24V 48V ... (CURRENT: 200A)
Closed

100A /200A /300A/500A LCD Combo Meter Voltage Current KWh Watt Meter 12V 24V 48V ... (CURRENT: 200A)

New 20 were available
R799.00
Shipping
R35.00 Standard shipping using one of our trusted couriers applies to most areas in South Africa. Some areas may attract a R30.00 surcharge. This will be calculated at checkout if applicable.
Check my rate
The seller has indicated that they will usually have this item ready to ship within 12 business days. Shipping time depends on your delivery address. The most accurate delivery time will be calculated at checkout, but in general, the following shipping times apply:
 
Standard Delivery
Main centres:  1-3 business days
Regional areas: 3-4 business days
Remote areas: 3-5 business days
Buyer protection
Returns
Replacement Guarantee: 7 Days: We stand by this guarantee
Get it now, pay later

Product details

Condition
New
Location
International
Bob Shop ID
645850495

SELECTED OPTION:
CURRENT: 200A

Overview: It is a basic multi-function instrument that can display various physical parameters such as voltage, current, power, capacity, energy, and operating time in real time. Overvoltage, undervoltage, overcurrent can be achieved through reserved relay interfaces. . And the meter uses 1.8-inch color LCD as a display, display data more comprehensive, clear and easy to observe. This meter is ideal for applications that require monitoring of the output voltage and current as well as applications such as charging and discharging batteries. Features: 1. The bidirectional detection current makes it easy for the user who detects the charge and discharge to detect the bidirectional current without changing the wiring direction. 2. Power-off memory function, able to memorize the number of AH and WH before power off after power off, which is convenient for observation and measurement. 3. time and AH number clear function, does not affect the next measurement. 4. The number of AHs can be filled up without affecting the direct discharge measurement. 5. voltage, current, charge capacity AH number, WH number, time, power at the same time display, display information is comprehensive and clear. 6. with output off function keys, flexible open or shut off the output. 7. with over-voltage, over-current protection. 8. when necessary, you can turn off the LCD display, reduce product power

1 measured voltage value
2 Measured current value
3 measured power value
4 Accumulated capacity or energy value
5 Battery Remaining Capacity Progress Bar
6 percentage of battery remaining capacity
7 Measured temperature ( Default withTemperature measurement function)
8 output status display
9 Total running time
10 Empty

Instructions:

1. AH, WH display switch, click to switch to display WH number, click to switch to display AH number.
2. Press OK key to enter the system parameter setting interface, then press OK key to switch the type of setting parameter. The set parameters include BAT, BPC, OPP, OVP, LVP, NCP, OCP, OTP, ADS, TTL, CLR, DTE. , Click to change the parameters, after the parameters are set, press OK to exit the parameter setting interface.

Function introduction:

1, BAT battery capacity value setting, this parameter is to set the battery measured total capacity.
2, BPC battery remaining capacity percentage, can be set according to the value of the remaining battery AH

4, OVP set over-voltage protection value, if the OVP value is set, when the actual measured voltage value is greater than the set value, it will prompt over-voltage, and cut off the relay (self-provisioned).
5, LVP set over-voltage protection value, if you set the LVP value, when the actual measured voltage value is less than the set value, it will prompt undervoltage, and cut off the relay (self-provisioned).
6, NCP set over-voltage protection value, if the NCP value is set, when the actual measurement of the charging current value is less than the set value, it will prompt over-current, and cut off the relay (self-provisioned).
7, OCP set over-voltage protection value, if the OCP value is set, when the actual measurement of discharge current value is less than the set value, it will prompt over-current, and cut off the relay (self-provisioned).
8, OTP set over-temperature protection value, if the OTP value is set, when the actual measured temperature value is greater than the set value, it will prompt the temperature, and cut off the relay (self-provisioned , Default withoutTemperature measurement function).
9, ADS communication address code settings. In multi-machine communication, multi-machine communication is achieved by setting the address code.
10, TTL instrument default relay output power state, normally open or normally closed.
11, CLR no-load current clear function, if the actual no-load current is zero


Package Included:

1 x100A /200A /300A/500A LCD Combo Meter







Recently viewed

See more
Bark Small Cylindrical Armed Strike Plate (110 x 40 x 15nmm)
New
R798.00
800x300x3mm Symphony Non-Slip And Odorless Mouse Pad(6)
New
R279.81
For Galaxy Grand Duos / i9082 / i9080 / i879 / i9128 Original Touch Panel Digitizer (White)
New
R248.40
1985 Complete Terror Claws Skeletor of He-Man-Masters of the Universe #10 (MOTU) Vintage Figure
Secondhand
R3,500.00 No bids