30-100A 230V LCD Display Single-phase Electric Watt-hour Meter DIN-rail Type Installation Household

New
-+
12 available
R781.00
Shipping
Standard courier shipping from R30
R30 Standard shipping using one of our trusted couriers applies to most areas in South Africa. Some areas may attract a R30 surcharge. This will be calculated at checkout if applicable.
Check my rate
Ready to ship in
The seller has indicated that they will usually have this item ready to ship within 12 business days. Shipping time depends on your delivery address. The most accurate delivery time will be calculated at checkout, but in general, the following shipping times apply:
 
Standard Delivery
Main centres:  1-3 business days
Regional areas: 3-4 business days
Remote areas: 3-5 business days
Returns
Replacement 7 Days
Replacement Guarantee: 7 Days: We stand by this guarantee
Get it now, pay later
Seller
Buyer Protection

Product details

Condition
New
Location
International
Bob Shop ID
615097812
Specification:
Model: DDS548C Type: Single-phase power meter Basic current: 30A Maximum current: 100A Frequency: 50Hz Reference voltage: 230V Current ratio: 1000imp/ kwh
Display: LCD Display Weight: About 0.28kg Product size: 100 * 76 * 65mm
Feature:
-- Use long life. -- 35mmDIN standard rail mounting
-- High reliability, small size, light weight, beautiful appearance and advanced technology. -- It has good anti-electromagnetic interference, low power consumption, high precision, high overload, high stability and anti-stealing.
? Use and scope of application: * Can directly and accurately measure the positive active energy in the electric energy metering, and the? 6-digit accumulator?display total power consumption. * This meter is suitable for measuring single-phase AC active energy with rated frequency of? 50Hz or 60Hz, for fixed installation indoors. It is suitable for ambient temperature? not exceeding -25?ᆪC~+55?ᆪC, relative humidity is not more than 95%, and not in air. Contains corrosive gases and prevents dust, mold, salt spray, condensation, insects and other effects.


Installation and use
* An electrician or professional with experience is required to install the meter and be sure to read this manual.

* In places where there is contamination and possible damage to the facility, the energy meter should be installed in a protective cabinet.
? * The electric energy meter with no lead seal or storage time should be re-inspected before the relevant department can be installed and used.
? * When the power meter is removed from the original box, the inner package or the outer casing is damaged. Do not install or power the meter.The electric energy meter should be installed in a ventilated and dry place indoors. It should be installed in? 35mm DIN standard?rail type.?The bottom plate of the electric energy meter should be fixed on the wall which is strong and refractory and not easy to vibrate. ? * When installing the wiring, it should be wired according to the wiring diagram on the electric energy meter case or the corresponding wiring diagram of the manual. It is best to use multi-strand copper wire to prevent the electric energy meter from working abnormally or burning due to poor contact. When the energy meter is properly connected to the power grid, the power indicator of the meter is always on.

Instructions for use * When the electric energy meter is used in areas with high lightning power, lightning protection measures should be taken to avoid damage to the electric energy meter due to lightning strikes. * The load capacity of the energy meter is between? 0.05Ib~Imax (direct access type)?or? 0.02Ib~Imax (via transformer connection type), which exceeds the transformer multiplier and is the actual power consumption. * Data display: meter display * Power indication: When the green light is on, it indicates that the working power of the energy meter is normal. * Pulse indication: When the red light is on, it indicates that the energy pulse is checked. * When there is a sampling signal, the pulse indicator lights up for about? 80ms.


Insulation performance * All the lines of the electric energy meter can withstand a surge voltage of? 1.2/50??S?and a peak value of? 6KV?between the outer casings, and test? 10 times?under the same polarity without arcing or breakdown. * All line-to-ground insulation of the energy meter can withstand an actual positive arc voltage of? 2KV?at a frequency of? 50Hz, which does not break down after one minute of testing. Note:?Please check that all programming is correct before using the meter.


Package Included:
1 x?Single-phase Electric Energy Meter








More from this seller

View all
R30 shipping
Halloween Party Home Decoration Black Cat Pumpkin Flag Toys For Kids Children Gift
R371
R30 shipping
for Huawei Mate 10 Pro Back Cover(Blue)
R264
R30 shipping
1pcs 100 * 220mm DIY Single-sided Green Oil PCB Universal Circuit Board
R328
R30 shipping
Air Purifier Filter Accessories for Dyson TP04 / DP04 / HP04Specification 1 set Filter + 1 ...
R1,248
Add to cart

Recently viewed

R30 shipping
G96 1.85 inch HD Square Screen Rugged Smart Watch Support Bluetooth Calling/Heart Rate Monitoring...
R1,205.44
R30 shipping
2010 2011 2012 2013 2014 VW POLO Hatchback 10- Mud Flap 4PCS / SET SHoleRT
R250

Similar products

R30 shipping
48% OFF
220V Repeat Cycle Timer, Programmable (220V AC, 8 Schedules, DIN Rail)
R419 R799
R30 shipping
JK11-5V 100S/15min/30min Delay Adjustable Infinite Loop Single-time Multi-func... (ITEM TYPE: 15MIN)
R342
R30 shipping
220V Single Phase Motor Soft Starter Module Controller 4KW
R1,895
R30 shipping
AT1-0750X 0.75KW 220V Single-phase Input Three-phase Output Inverter
R2,204