Feature: Product Name: Digital display embedded cabinet thermostat Product model: XH-W2060 Temperature range: -19~99 C Control range: -19~99 C Temperature control accuracy: 1 C Measurement input: NTC10K waterproof probe L = 1 m Refresh rate: 4 times / sec Use environment: -30~60C Humidity 20%-85% Use environment: 12/24/220V optional Output type: Relay output up to 10A Appearance size: 77 x 62 x 34.5mm Opening size: 71 x 29mm Other functions: Power-off memory, state memory, temperature correction, delay start
Code | Code Description | Setting Range | Factory settings | Unit |
P0 | Operating mode | C/H | C | / |
P1 | Hysteresis setting | 0.1-50 | 2 | C |
P2 | Temperature correction | -9~9 | 0 | C |
P3 | Delayed start | 0-9 | 0 | Minute |
P4 | High temperature alarm | -19~99 | 99 | C |
P0: Temperature control mode C: Cooling mode H: Heating mode P1: Difference setting For example: P1=5 Cooling mode: When the detected temperature reaches the stop temperature, the relay is disconnected, the cooling is stopped, the temperature rises by 5 C, and the relay closes again. Heating mode: When the detected temperature reaches the stop temperature, the relay is disconnected, the heating is stopped, the temperature drops back to 5 C, and the relay closes again. P2: Temperature correction If the detected temperature and the actual temperature deviate, you can use this function to correct. Actual value = measured value + corrected value. For example, if the measured temperature is 25 C and the actual temperature is 26 C, then P2 can be set to 1, then The final temperature is 25+1=26 P3: Delayed start This function is used for compressor cooling. If it is used in a refrigerator freezer, this value must be set. According to the compressor back pressure, the value is usually set to 3-6 minutes. P4: High temperature alarm Set the high temperature alarm value. When the detected temperature exceeds this value, the screen flashes and the buzzer sounds an alarm.
Package includes: 3 xDigital display embedded cabinet thermostat