9Pcs MQ2 MQ-3 MQ-4 MQ-5 MQ-6 MQ-7 MQ-8 MQ-9 MQ-135 Sensor Module kit

9Pcs MQ2 MQ-3 MQ-4 MQ-5 MQ-6 MQ-7 MQ-8 MQ-9 MQ-135 Sensor Module kit

3 available / new
Indicative market price: R439.00
Only 3 left – grab it before it’s gone!
R399.09
Shipping
R35.00 Standard shipping using one of our trusted couriers applies to most areas in South Africa. Some areas may attract a R30.00 surcharge. This will be calculated at checkout if applicable.
Check my rate
The seller has indicated that they will usually have this item ready to ship within 2 business days. Shipping time depends on your delivery address. The most accurate delivery time will be calculated at checkout, but in general, the following shipping times apply:
 
Standard Delivery
Main centres:  1-3 business days
Regional areas: 3-4 business days
Remote areas: 3-5 business days
Seller
Buyer protection
Get it now, pay later

Product details

Condition
New
Location
South Africa
Product code
1040
Bob Shop ID
638464464

Features

MQ-2:
Detection concentration: 300-1000ppm(combustible gas).

MQ-3:
Used in motor vehicles and other no drunken drivers homework personnel on-site testing, also used in other places of ethanol vapor detection.

Size: 32 x 22 x 27mm
Main chip: LM393, ZYMQ - 3 gas sensors
Working voltage: DC 5V
1, With a signal output instructions.
2, Two-way signal output (TTL level output and analog output)
3, TTL output signal for low level effectively.(when the low output electric signal lights at ordinary times, can be directly by single chip microcomputer)
4, Analog 0 - 5V voltage, the higher the concentration, the higher the voltage.
5, To ethanol steam has a high sensitivity and good selectivity.
6, In June and has long service life and reliable stability.
7, Rapid response recovery features.


MQ-4:

1, Using high-quality dual-panel design, with power indicator and TTL signal output instructions;
2, With a DO switch signal (TTL) output and AO analog signal output;
3, TTL output valid signal is low. (When the output low signal light can be directly connected microcontroller or relay module)
4, The analog output voltage, the higher the concentration the higher the voltage.
5, Methane, natural gas has better detection sensitivity.
6, There are four screw holes for easy positioning;
7, Product Dimensions: 32 (L) * 20 (W) * 22 (H)
8, With a long service life and reliable stability
9, Rapid response and recovery characteristics
 
Electrical properties
Input voltage: DC5V power (current): 150mA
DO output: TTL digital 0 and 1 (0.1 and 5V)
AO output :0.1-0 .3 V (relatively clean), the highest concentration of voltage around 4V

MQ-5:

Suitable for home or industrial on LPG, natural gas, coal gas monitoring devices. Excellent resistance to alcohol, smoke interference.


1, Using high-quality dual-panel design, with power indicator and TTL signal output instructions;
2, With a DO switch signal (TTL) output and AO analog signal output;
3, TTL output valid signal is low. (When the output low signal light can be directly connected microcontroller or relay module)
4, The analog output voltage, the higher the concentration the higher the voltage.
5, For gas, natural gas has better detection sensitivity.
6, There are four screw holes for easy positioning;
7, Product Dimensions: 32* 20 * 22
8, With a long service life and reliable stability
9, Rapid response and recovery characteristics
 
Electrical properties
Input voltage: DC5V power (current): 150mA
DO output: TTL digital 0 and 1 (0.1 and 5V)
AO output :0.1-0 .3 V (relatively clean), the highest concentration of voltage around 4V

MQ-6:

Suitable for domestic or industrial on LPG (liquefied petroleum gas), butane, propane, LNG (liquefied natural gas) detection devices. Excellent resistance to ethanol vapor, smoke interference.

1, Using high-quality dual-panel design, with power indicator and TTL signal output instructions;
2, With a DO switch signal (TTL) output and AO analog signal output;
3, TTL output valid signal is low. (When the output low signal light can be directly connected microcontroller or relay module)
4, 0 ~ 5V analog output voltage, the higher the concentration the higher the voltage.
5, The propane, butane, LPG, LNG has a good detection sensitivity.
6, There are four screw holes for easy positioning;
7, Product Dimensions: 32 (L) * 20 (W) * 22 (H)
8, With a long service life and reliable stability
9, Rapid response and recovery characteristics
 
Electrical properties
Input voltage: DC5V power (current): 150mA
DO output: TTL digital 0 and 1 (0.1 and 5V)
AO output :0.1-0 .3 V (relatively clean), the highest concentration of voltage around 4V

MQ-7:

For home, carbon monoxide detection device environment. Suitable for carbon monoxide and gas detection.

Detection of concentration: 10-1000ppmCO
Loop voltage Vc: <=10V DC
Heater voltage Vh: 5.0V ±0.2V  ACorDC(high)
Load resistance: adjustable.
Heater  resistance RH: 31ohm ± 3 ohm(room temperature)
Heater power consumption PH: <=350mW

Standard test conditions
Temperature: 20 degree ± 2 degree
Humidity: 65% ± 5% RH
Standard test circuit: Vc: 5.0V ± 0.1V; Vh(high):5.0V±0.1V
                                   Vh(low):1.5V±0.1V

1, The analog output voltage, the higher the concentration the higher the voltage.
2, The carbon monoxide detection with better sensitivity.
3, There are four screw holes for easy positioning;
4, Product Dimensions: 32 (L) * 20 (W) * 22 (H)
5, With a long service life and reliable stability
6, Rapid response and recovery characteristics
 
Electrical properties
Input voltage: DC5V power (current): 150mA
DO output: TTL digital 0 and 1 (0.1 and 5V)
AO output :0.1-0 .3 V (relatively clean), the highest concentration of voltage around 4V

MQ-8:

Suitable for domestic or industrial hydrogen leak on a monitoring device. Are not subject to ethanol vapor, soot, carbon monoxide and other gases interference.

MQ-9:

For home or factory gas leak detection device, suitable for carbon monoxide, combustible gas monitoring device.

Can test carbon monoxide: 10 to 1000ppm CO
Combustible gas range: 100 to 10000ppm

Loop voltage Vc: <=10V DC
Heater voltage Vh: 5.0V ±0.2V  ACorDC
Heater resistance: 31 ohm ± 3 ohm(room temperature).
Heater power consumption PH: <=900mW
Standard test conditions:
Temperature: 20 degree ± 2 degree
Humidity: 65% Note: Stock is currently available in South Africa for national shipping!

Add to cart

Recently viewed

Securnix 4 way Power Splitter
R93.00
Tecno Spark 6 Go LCD Screen - LCD Touch Digitizer Assembly with Tools KE5j KE5k KE5S (Local Stock)
R580.00
HIGH OMPACT CONSULTING HOW CLIENTS & CON SECONDHAND - SCHAFFER,R
R352.00

Similar products

3pcs MQ-4B Sensor Gas Sensor CO CO2 Smoke Methane Sensor Detecting MQ Sensor DIY for Safety Detectio
R356.00
Mq 3 Alcohol / Ethanol Gas Sensor Board Md0201 Mq3
R83.94
MQ-5 liquefied Gas Methane Sensor Module
R80.67
10pcs MQ-4B Sensor Gas Sensor CO CO2 Smoke Methane Sensor Detecting MQ Sensor DIY for Safety Detecti
R482.00