Bluetooth relay manual:
NO : Relay normally open contact
COM : Relay common contact
NC : Relay normally closed contact
Momentary : Mobile terminal input A0, the relay is open,and after delay of 1 second the relay is Close.
Self-locking : Mobile terminal input A1, the relay is Open, input A1, the relay is Close, and so on
Open : NO connection COM, NC disconnect COM
Close : NO disconnect COM, NC connection COM
External trigger input: low pulse triggering, pulse width greater than 200 milliseconds.
Two control methods, external trigger signal and Command Control,It can be composed of flexible and diverse control.
CommandS(Format:character, case-insensitive)
CommandS | Features | Description |
A0 | Momentary | Mobile terminal input A0, the relay is open,and after delay of 1 second the relay is Close. |
A1 | Self-locking | Mobile terminal input A1, the relay is Open, input A1, the relay is Close, and so on |
A2 | Open | NOconnection COM, NCdisconnect COM |
A3 | Close | NOdisconnect COM, NCconnection COM |
A4 | Open | NOconnection COM, NCdisconnect COM |
Bluetooth APP operations:
Access Password:1234
Bluetooth Baud rate: 9600BPS