This item has closed 3 buyers bought 3 items
View other items offered by Wuzland1113

Similar products

R30 shipping
PH-029 Multi-point Wireless Remote Control Digital Online PH Monitor Meter Water Quality Monitor PH
R1,978
R30 shipping
PH-025M Digital PH Meter Tester Hydroponic Pool Water Aquarium Monitor
R1,369
R30 shipping
Digital PH Meter Water Quality Tester PH Tester Aquarium PH Monitor Equipped With ... (PLUG: EUPLUG)
R1,000
R30 shipping
PH-991 PH Meter with Backlight Tester Durable Acidimeter Tool Temp Monitor for Aquarium Swim Pool Wa
R1,241

Digital PH Meter PH02 (Upgraded) for Easy Calibration

New
R209.00
Closed 14 Aug 22 20:31
Shipping
Standard courier shipping from R30
R30 Standard shipping using one of our trusted couriers applies to most areas in South Africa. Some areas may attract a R30 surcharge. This will be calculated at checkout if applicable.
Check my rate
Free collection from Beyers Park, Boksburg
The seller allows collection for this item and will be in contact with the full collection address once the order is ready. Ready for collection by Friday, 31 May.
Ready to ship in
The seller has indicated that they will usually have this item ready to ship within 2 business days. Shipping time depends on your delivery address. The most accurate delivery time will be calculated at checkout, but in general, the following shipping times apply:
 
Standard Delivery
Main centres:  1-3 business days
Regional areas: 3-4 business days
Remote areas: 3-5 business days
Get it now, pay later
Buyer Protection

Product details

Condition
New
Location
South Africa
Customer ratings:
Product code
PH02
Bob Shop ID
562580310

Digital PH Meter-PH02 Upgraded for More Accuracy 

Specifications:

  • PH testing range: 0.00 to 14.00
  • Resolution: 0.01 pH
  • Accuracy: +/- 0.01 pH (20 degree)
  • Working temperature: 0 to 60 degree
  • Weight: 51 grams
  • Dimensions: Length 155 mm, Width 31 mm

This digital PH meter package includes:

  • One meter device with 2 batteries (AG13/LR44).
  • One manual for instruction and calibration.
  • Two sachets of PH buffer powder (Default pH4.01 and pH6.86, or pH6.86 and pH9.18 if required.)
  • One plastic box

Importance:

  1. The glass electrode is fragile, avoid to be touched or hit, always keep the cap closed while not using, no guarantee for its damage.
  2. The device is pre-calibrated by the manufacturer, not necessary to calibrate it before using. We also retest it before sending out. However you may calibrate it if you feel incorrect.
  3. The calibration is recommended, after 2 to 3 months if the testing has not be done too often, or when the accuracy is required.
  4. Calibrate the tester with PH 6.86 buffer powder firstly, then the PH 4.01 or PH 9.18 ones. Should the sample to be tested be acidic, the tester can be calibrated with buffer powder of PH 4.01 and 6.86, while it's alkaline, PH 6.86 and 9.18 ones should be used for calibration. Calibration with these three types of buffer powder is recommended if the tester will be used to test the PH of acid and alkaline. The calibration for this device is computerized and not done manually with a screw driver, read the instruction in the manual or tips below.
  5. Maintenance, should the device not be used for a long period, simply test it with the clean water every half month.
  6. Testing instruction: sway the  device gently against the tested liquid while testing (this may take a while), after the reading is unchanged, then stop and take the reading. Do NOT press the CAL button if not to calibrate, this may cause error.
  7. The pH of tested liquid should be within pH 0 to 14 and its temperature also in 0 to 60 degree, otherwise the detection bulb may be broken if to test the liquid out of these ranges.
  8. Images 3 to 7 were PH testing examples of the seller's fish pond. Never guess the PH, it will cost your fishes' lives.

Calibration Tips (Seller's experiences, our products only)

  1. Detector have to be immersed in the buffer liquid during the calibration, and stirred in the liquid for a while before the reading is unchanged. The detector should be rinsed with pure water before calibration with other buffer liquid.
  2. There are some types of calibration programmed in the chips, most of them the calibration is done by simply press the CAL button, and the device will detect the buffer liquid automatically, 4.01, 6.86 or 9.18 flashing in the screen. If an error or "- - - -" appears you after you press CAL button (and hold), then you have to try to calibrate with other buffer liquid, such as 4.01 one, then go back the calibrate with error one. Do the calibration according to the manual.
  3. Cautions: The calibration procedure is programmed, PH6.86 has to be done firstly after CAL button is pressed. Should there be any mistakes done during the procedure, do not repeat, but switch off, and do the calibration from the beginning. Should this not work, try the procedure above mentioned to settle the error. Should the batteries are flat (working but reading unclear), the calibration may not be done correctly (error occurs), replace the batteries for calibration.

Optional Purchase:

Spare LR44/AG13 button batteries (2 needed for this device) and additional sachets of buffer powder are available to buy without extra shipping cost if needed. Please write your selection in "Note to seller" or send us message, otherwise it's default to our choice to send.

Please visit our selling list to buy any quantities of Buffer Powder, spare AG13/LR44 button batteries or other types of pH testing pens, "Add to cart" works for the different small items you purchase from us to be checked out in one order with no extra shipping cost.

This PH tester can be used to test PH for cold drink and juice, watered chemicals and pharmaceuticals, swimming pool and tap water, etc. Calibration should be done regularly while testing in the labs and accuracy required.

The device will be tested working before sending to the buyers.

More from this seller

View all
Button Lithium Batteries (Coin Battery, CR2032, Min. 10 batteries to take )
R13.50
64% OFF
Wuzland® VG Only E-liquid for Electronic Cigarettes (1x10ml) on Sale
R25 R70
R30 shipping
E-cigarette Kit - EVOD 1100mah Battery with T3D Atomizer - Refilled E-liquid Smoking
R250
Wuzland® Tobacco and Cigarettes Flavors 10ml Eliquid @SPECIAL (All MGS)
R29

Customer ratings: 1 ratings

Thanks, great Seller
27 Oct 2022