Main centres: | 1-3 business days |
Regional areas: | 3-4 business days |
Remote areas: | 3-5 business days |
EN:
EN:3
2.Uptime and installation conditions
Control device; built-in controller
2.1 Ambient air temperature
Product structure: non power off, rail type, high current, small volume, two-stage,
The maximurn temperature shall not exceed 40 C, the minimum temperature shail
simple structure, ATS integration
not be lower than-5 , and the average temperature within 2An shail not bes higher
Features: fast switching speed, low faiture rate, convenient maintenance and
reliable performance
than 35 .
Wiring mode: front plate wiring
2.2 Altitude
Conversion mode: grid to grid
The atude of the instalation site shall not be higher than 2000m.
Product shell frame: 100
2.3 Atmospheric conditions
Product current: 10, 16, 20, 25,32,40,50,63, 80, 100A
the occasional condensation on the product surface. When the maximum temperature reaches 40 C, the relative humicity of the 90%.Due to temperature changes, special measures should be taken to deal wth humidity is high, for example, the temperature is 25 C,and the relative humidty is installation site should not exceed 50%;When the temperature is-5 C,the mlative
Product classification: direct load type Number of poles: 2, 3, 4
Product standard: GB/T14,048.11 AT SE: PC level
2.4 Pollution level
Switching time: 0.008 seconds/8 ms
ATS pollution level shall conform to the specified level 3 in GB/T14048.11.
2.5 installation category
1.Product Overview
The installation type of ATS shall conform to the category specifed in GB/T14048. t1.
The dual power automatic switch is a newly developed miniature household power 2.6 installation conditions
power supply is normal. When the normal ower supply is abnormal, the standby power supply will immediately start to work, so as to ensure the continuty, relabilty switch. This switch is mainly used to test whether the main power supply or standby Ensure that the installation distance meets the requirements in Figure 1 ATS can be vertically installed in control cabinet or power distribution cabinet.
and safety of power supply. This product is specially designed for household rall 3 Model and its meaning
installation, and is specially used for PZ30 distribution box. 100A
The dual power automatic transfer switch is applicable to the emergency power supply system with 50 or 60Hz and rated 400V alternating current. ATs is
characterized by solid structure, reliable conversion, convenient installation and Current class
maintenance, and long service life.It is widely used in various occasions where
ATS is composed of TSE and controller. power fallure cannot be sustained. It can be operated either by electricity or manually. Current class
Enterprise code
What's in the box
1xdual Power Converter Switch Q-Kg900