Specifications
Maximum voltage between any terminal and earth ground 600 V
Safety IEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT III 600V
Fuse for A input 11 A, 1000 V FAST Fuse (Fluke PN 803293)
Display Digital: 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating temperature -10°C to +50°C
Storage temperature -40°C to +60°C
Battery type 9 volt Alkaline, IEC 6LR61
Battery life 400 hours typical, without backlight
Accuracy Specifications
DC millivolts Range/resolution 600.0 mV / 0.1 mV
Accuracy ±([% of reading] + [counts]): 0.5% + 2
DC volts Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy ±([% of reading] + [counts]): 0.5% + 2
Auto volts Range/resolution 600.0 V / 0.1 V
Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts¹ True RMS Range/resolution 600.0 mV / 0.1 mV
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts¹ True RMS Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity Range/resolution 600 / 1
Accuracy Beeper on < 20 , off > 250 detects opens or shorts of
500 s or longer.
Ohms Range/resolution 600.0 / 0.1
6.000 k / 0.001 k
60.00 k / 0.01 k
600.0 k / 0.1 k
6.000 M / 0.001 M
Accuracy 0.9% + 1
Range/resolution 40.00 M / 0.01 M
Accuracy 5% + 2
Diode test Range/resolution 2.00 V / 0.001 V
Accuracy 0.9% + 2
Capacitance Range/resolution 1000 nF / 1 nF
10.00 F / 0.01 F
100.0 F / 0.1 F
9999 F / 1 F
100 F to 1000 F
Accuracy 1.9% + 2
Range/resolution > 1000 F
Accuracy 5% + 20%
Lo-Z capacitance Range 1 nF to 500 F
Accuracy 10% + 2 typical
AC amps True RMS (45 Hz to 500 Hz) Range/resolution 6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy 1.5% + 3
20 A continuous overload for 30 seconds max
DC amps Range/resolution
6.000 A / 0.001 A 10.00 A / 0.01 A
Accuracy 1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)² Range/resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 Hz
50.00 kHz / 0.01 Hz
Accuracy 0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.