This item has closed with no items sold
View the relisted Item
View the relisted Item
View other items offered by szulou1670

Similar products

R30 shipping
Aqua Water Timer Mechanical 15min to 120min
R438
JK11-5V Delay Adjustable Infinite Loop Relay Module
R92
R30 shipping
3pcs JK11-PB Time Delay Relay Module 0-100S Adjustable Delay 0.5S Open for Computer Automatic Start
R409
R30 shipping
JK11-5V 100S/15min/30min Delay Adjustable Infinite Loop Single-time Multi-func... (ITEM TYPE: 15MIN)
R342

JK11-5V 100S/15min/30min Delay Adjustable Infinite Loop Single-time Multi-func... (ITEM TYPE: 15MIN)

New
R342.00
Closed 11 May 24 00:04
Shipping
Standard courier shipping from R30
R30 Standard shipping using one of our trusted couriers applies to most areas in South Africa. Some areas may attract a R30 surcharge. This will be calculated at checkout if applicable.
Check my rate
Ready to ship in
The seller has indicated that they will usually have this item ready to ship within 15 business days. Shipping time depends on your delivery address. The most accurate delivery time will be calculated at checkout, but in general, the following shipping times apply:
 
Standard Delivery
Main centres:  1-3 business days
Regional areas: 3-4 business days
Remote areas: 3-5 business days
Returns
Replacement 7 Days
Replacement Guarantee: 7 Days: We stand by this guarantee
Get it now, pay later
Buyer Protection

Product details

Condition
New
Location
International
Bob Shop ID
612371027

SELECTED OPTION:
ITEM TYPE: 15MIN



Specifications: ? Voltage: 5V DC Quiescent current: 8mA Operating current: 95mA Trigger: passive switch trigger, response time is 0.03 seconds (the trigger terminal can not access the active signal) Minimum on-off time: 0.2 seconds Load capacity: 10A Output form: normally open + normally closed Size: 70*20*19mm
Features: ? - Using industrial-grade single-chip microcomputer to control time, high precision and stable performance; - Two adjustable resistors are used to adjust the time, and the connection duration and the disconnection time can be independently adjusted; - The external contact is activated, and the timing is started by shorting the self-reset button. It is also possible to start the countdown by shorting the triggers together to achieve power-on; - The time range is divided into 0-100 seconds, 0-15 minutes, and 0-30 minutes. ? Basic working principle: ? Taking the factory standard setting as an example, the red LED will light when the power is turned on, and the relay is in the off state. When shorted at the trigger end, the module green light is on and immediately enters the working state. Triggering again in the working state will stop working. In the working state, the relay will pass T1 seconds, break T2 seconds, pass T1 seconds, break T2 seconds... infinite loop. T1 T2 is the length of time the user adjusts with an adjustable resistor. ? Instructions: ? - Power access: The module is connected to the power supply according to the correct power supply voltage and polarity. The red line of the power supply terminal is positive and the black line is negative. - Trigger line access: The two white lines of the trigger end are connected to a switch, and the module can be started by tapping the switch, and then the switch is stopped by tapping the switch. The trigger switch can be a tact switch, a micro switch, an optocoupler C-E terminal, a relay contact, and the like. - Normal speed and quick mode settings: The OP1 jumper is used to select normal speed and fast mode, and the shipment defaults to normal speed. - Loop mode and single mode settings: The OP2 jumper is used to select the loop mode and the single mode, and the shipment defaults to the loop mode. Cycle mode: After starting, the relay is on-off-on-off-disconnect..., and it is cycled according to the set duration; Single trigger: After starting, the relay is turned on, and the relay is turned off after T1 duration. (After disconnection, the action ends and waits for trigger again) ? Precautions:
? 1. The module power supply is not protected against reverse protection, because it is important to remember that the power supply cannot be connected. 2. The trigger terminal can only be connected to the passive switch, not to the voltage signal. Doing so can damage the module. 3. When the resistance load is connected, no special treatment is needed; when the capacitive load is connected, the relay module is easily damaged by electricity. It is recommended to use the AC contactor derated or the contact current of the motor should be considered within 10A.
4.Borad Number: (marker adjustable delay time) 1=15min 2=100S 3=30min ? Package Included: ? 1 x JK11-5V 100S/15min/30min Delay Adjustable Multi-function Relay Module ?






More from this seller

View all
R30 shipping
Original Version Touch Panel for iPad mini / mini 2 Retina(White)
R341
R30 shipping
Car Rearview Mirror Cover for Volvo Xc60 2018-2020 39844970 39844955
R1,094
R30 shipping
Pu Tissue Box Multifunctional Desktop Organizer (black)
R768
R30 shipping
Original Xiaomi Mijia T500 Smart APP Electric Toothbrush IPX7 Waterproof Chargeable UV Sterilizat...
R846

Recently viewed

R30 shipping
Power Button & Volume Button Flex Cable for Xiaomi Mi Note 3
R210
R30 shipping
44% OFF
***BEAUTIFUL 18K WHITE GOLD PLATED ETERNITY WEDDING RING, SIZE 5, 6, 7.5
R195 R350