JK11S-100S-5V 10A 0-100S Adjustable ON-OFFf Delay Module Timer Cycle Switch Infinite Loop Relay Modu JK11S-100S-5V 10A 0-100S Adjustable ON-OFFf Delay Module Timer Cycle Switch Infinite Loop Relay Modu
JK11S-100S-5V 10A 0-100S Adjustable ON-OFFf Delay Module Timer Cycle Switch Infinite Loop Relay Modu JK11S-100S-5V 10A 0-100S Adjustable ON-OFFf Delay Module Timer Cycle Switch Infinite Loop Relay Modu

JK11S-100S-5V 10A 0-100S Adjustable ON-OFFf Delay Module Timer Cycle Switch Infinite Loop Relay Modu

20 available / new
R373.00
Shipping
R35.00 Standard shipping using one of our trusted couriers applies to most areas in South Africa. Some areas may attract a R30.00 surcharge. This will be calculated at checkout if applicable.
Check my rate
The seller has indicated that they will usually have this item ready to ship within 12 business days. Shipping time depends on your delivery address. The most accurate delivery time will be calculated at checkout, but in general, the following shipping times apply:
 
Standard Delivery
Main centres:  1-3 business days
Regional areas: 3-4 business days
Remote areas: 3-5 business days
Seller
Buyer protection
Returns
Replacement Guarantee: 7 Days: We stand by this guarantee
Get it now, pay later

Product details

Condition
New
Location
International
Bob Shop ID
641126776
Specifications: Voltage: 5V DC Quiescent current: 8mA Operating current: 95mA Trigger: passive switch trigger, response time is 0.03 seconds (the trigger terminal can not access the active signal) Minimum on-off time: 0.2 seconds Load capacity: 10A Output form: normally open + normally closed Size: 70*20*19mm Features: - Using industrial-grade single-chip microcomputer to control time, high precision and stable performance; - Two adjustable resistors are used to adjust the time, and the connection duration and the disconnection time can be independently adjusted; - The external contact is activated, and the timing is started by shorting the self-reset button. It is also possible to start the countdown by shorting the triggers together to achieve power-on; - The time range is divided into 0-100 seconds. Basic working principle: Taking the factory standard setting as an example, the red LED will light when the power is turned on, and the relay is in the off state. When shorted at the trigger end, the module green light is on and immediately enters the working state. Triggering again in the working state will stop working. In the working state, the relay will pass T1 seconds, break T2 seconds, pass T1 seconds, break T2 seconds... infinite loop. T1 T2 is the length of time the user adjusts with an adjustable resistor. Instructions: - Power access: The module is connected to the power supply according to the correct power supply voltage and polarity. The red line of the power supply terminal is positive and the black line is negative. - Trigger line access: The two white lines of the trigger end are connected to a switch, and the module can be started by tapping the switch, and then the switch is stopped by tapping the switch. The trigger switch can be a tact switch, a micro switch, an optocoupler C-E terminal, a relay contact, and the like. - Normal speed and quick mode settings: The OP1 jumper is used to select normal speed and fast mode, and the shipment defaults to normal speed. - Loop mode and single mode settings: The OP2 jumper is used to select the loop mode and the single mode, and the shipment defaults to the loop mode. Cycle mode: After starting, the relay is on-off-on-off-disconnect..., and it is cycled according to the set duration; Single trigger: After starting, the relay is turned on, and the relay is turned off after T1 duration. (After disconnection, the action ends and waits for trigger again) Precautions: 1. The module power supply is not protected against reverse protection, because it is important to remember that the power supply cannot be connected. 2. The trigger terminal can only be connected to the passive switch, not to the voltage signal. Doing so can damage the module. 3. When the resistance load is connected, no special treatment is needed; when the capacitive load is connected, the relay module is easily damaged by electricity. It is recommended to use the AC contactor derated or the contact current of the motor should be considered within 10A. Package Included: 1 x JK11S-5V 100S Delay Adjustable Multi-function Relay Module





Add to cart

Recently viewed

See more
ARDUINO NANO I/O BREAKOUT SHIELD EB0023
R69.40
HPE Broadcom BCM5719 4-port 1GbE BASE-T OCP3 Network Adapter
R4,197.71
Autel MS906 PRO (Upgrade of MS906BT) | Advanced Diagnostic Scan Tool (Coding, Actuations etc)
R27,499.00
3D Patterns for the Scroll Saw : Ready-to-Cut Patterns for 45 Unique Projects - Softcover
R50.00

Similar products

50% OFF
DC 5-30V MOS LED Display Automation Cycle Delay Timer Module Switch Control Delay Time Relay
R193.00 R386.00
JK11-5V Delay Adjustable Infinite Loop Relay Module
R92.00
QF1022-A-100S 220V AC Power-on Delay 0-100S Adjuatable Timer Switch Automatic Disconnect Relay Modul
R393.00
QF1023-A-10S Timing Relay Delay Switch Relay Delay Timer Switch Timing Relay 10S Adjustable
R353.00