R35.00 Standard shipping using one of our trusted couriers applies to most areas in South Africa. Some areas may attract a R30.00 surcharge. This will be calculated at checkout if applicable. Check my rate
There are various locker and counter collection points across South Africa. View locations
The seller allows collection for this item. Buyers will receive the collection address and time once the order is ready.
The seller has indicated that they will usually have this item
ready to ship within 3 business days.
Shipping time depends on your delivery address.
The most accurate delivery time will be calculated at checkout,
but in general, the following shipping times apply:
Mecer has been one of South Africa's top-selling PCs over the past two decades. Mustek's ongoing interaction within the international IT industry has ensured that Mecer has remained a techno-leader at the forefront of technology. **Please note that batteries are not included and needs to be bought separately** This unit is also intended for use with IT equipment and will not be able to run a kettle, heater or anything that uses a motor or an element. Features: - Simulated sine wave inverter - Built-in AVR for voltage regulation - Wide input voltage range: 90-280 VAC - 12VDC available - Overload and short circuit protection - LCD display for comprehensive information Specifications: - MODEL Mecer IVR-1200LBK - CAPACITY 1200 VA / 720 W - POWER FACTOR 0.8 - Input Voltage range 90-280VAC Line Mode: - Output Voltage - Bypass mode: 0utput voltage same as input voltage - AVR mode: Output voltage = Input voltage 1.2 at Input voltage - Output Frequency Same as input Battery Mode (BATTERIES NOT INCLUDED): - Output Voltage 230Vac +/-10% - Transfer Time 20ms typical - Waveform Modified Sine-wave Overload Capability: - Bypass Mode (in VA and Watts) Load >110%+/-15% , alarm 5 mins then fault - Load >130% +/-15%, fault immediately. - AVR Mode (in VA and Watts)at Input voltage > 170VAC Load >100%+/-15%, go to bypass mode - AVR Mode (in VA and Watts)at Input voltage < 170VAC Load >60%+/-15%, go to bypass mode - Battery Mode (in W) Load>110% +/-15%, overload alarm for 15s, and then will switch to fault mode for 10s. Then unit will re-start for 5 times Load>120% +/-15% , fault & cut off O/P immediately. Short Circuit Protection: - Line Mode Breaker - Battery Mode Current limit +Firmware Protection Battery specs needed (NOT INCLUDED): - Battery Voltage 12VDC - Acceptable Battery Type Rechargeable lead-acid battery, Deep discharge battery - Polarity Reserve Protection Yes - Charger available I/P range 90 280V Charger: - Constant Current Charger Voltage 14.3VDC +/-2% - Floating Charge Voltage 13.7VDC +/-2% - Maximum Charge Current 10A or 20A - DC Start Voltage >11VDC Physical: - Dimension, D X W X H (mm) 350 x 90 x 300 - Net Weight (kgs) 4.5 Environment: - Operating Humidity 0 to 90% Relative Humidity(Non-condensing) - Operating Temperature 0 degrees C to 40 degrees C - Storage Temperature -15 degrees C to 50 degrees C