Key Features
True double-conversion design with high adaptability to harsh mains conditions
DSP design enables precise and reliable control
High efficiency results in energy saving
Supports energy-saving ECO mode
Compact size requiring small installation space
Built-in OVCD protection, fan lock detection, over temperature detection, overload warning to enhance the product reliability
USB HID enable monitoring on UPS without software installation
Intelligent communication slot enables remote monitoring
Programmable LCD display for quick UPS parameters configuration
Low audible noise at typical load
MBP+PDU with load segment control
Typical application
Financial
Work station
Network equipment
Healthcare
Telecom
Specifications
Power Rating
VA/Watt: 6000VA/6000W
Double conversion mode: 95%
ECO mode: 98%
Input performance
Rated voltage: 220/230/240V
Voltage range: 160-275V 100% load, 110-160V derating to 50% load linearly
Rated frequency: 50Hz/60Hz
Frequency range: 40Hz-70Hz (45Hz-55Hz 54Hz-66Hz @ load>60%)
PF: >0.995
THDI: <3% linear load
<5% non linear load
Input connection
L/N/PE hardware terminal connection
Output performance
Rated voltage: 220/230/240V
Rated frequency: 50Hz/60Hz
Maximum PF: 1
Voltage accuracy: +/-1%
THDv: <1% linear load
<5% non linear load
Transfer time: 0ms(10ms @ ECO->Inverter)
Crest Ratio: max3:1
Overload: 100%
105%
125%
150% for 500ms
Output connection
Wiring/socket: L/N/PE hardware terminal connection
Load segment control: Optional (need MBP model)
Battery
Voltage: 192VDC(192-240VDC adjustable)
Capacity(AH): NA
Maximum connect external battery module quantity: 6
Charger
Charging current: 4A(0-12A adjustable)
Other working mode
CVCF: Yes (derating to 60% load)
Parallel: Optional (up to 3)
HMI
Display: Dot matrix LCD, rotatable manually
USB: USB 2.0 with HID
RS232: Yes(DB9)
Dry in/out: 1 programable dry in; 1x programable dry out
EPO: yes
Intelligent slot: yes(for long card)
Network card Installed, NMC long card
Modbus card: Optional,CMC/Modbus Long Card
Dry contractor card: Optional,AS400 Long Card
Monitor software: Winpower
Physical performance
Dimension (W x D x H) mm: 438 x 573 x 86.2 (power module, 2U)
Net weight (kg): 14
IP protection level: IP20
Environment
Operating temperature: 0-50°C (power derating to 50% @ 40-50°C
Relative Humidity: 0-95%
Operating Altitude: 0-3000m (the load derating 1% every up 100m @1000-3000m)
Acoustic Noise: <50dB @ typical load with battery fully charged
What's in the box
1x Mecer 6KVA Rackmount UPS
1x SNMP card
1x EBM cable
1x USB cable
1x Rail kit
1x Tower Feet
1x Rack ear
1x Manual