The manufacturers do NOT recommend using a UPS / Inverter for instances of load shedding from Eskom. These devices are designed to provide backup power to equipment to shut down gracefully so that no data is lost, or long enough until a secondary AC source, like a generator, comes online. Battery performance will significantly deteriorate when they are discharged and recharged continuously such as in cases of load shedding.
Please note the limitations of each battery technology:
Due to the above limitations, the manufacturers consider batteries as consumables, and only offer a limited warranty. Loss of capacity is not covered under warranty.
Winner Pro is specifically designed for operation in poor power areas. They provide high power density with long backup time in a compact size. Its ideal for ATMs, banking and other business-critical applications. Users also can adjust the charging current from 1A to 6A according to different applications.
Unique Features
- True double-conversion online UPS
- Microprocessor control guarantees high reliability
- Wide input voltage range (110- 300 VAC)
- Input power factor correction 0.99
- Output power factor 0.8
- 50/60 Hz Frequency Converter Mode
- ECO mode operation for energy saving
- Smart SNMP works well with either USB or RS- 232 together
- Optional isolation transformer available
Specifications
- Model : RCT- 3000- WPTU
- Phase : Single phase with ground
- Capacity : 3000 VA/2400 W
Input
- Nominal Voltage : 100/110/115/120/127 VAC or 200/208/220/230/240 VAC
- Voltage Range : 55- 150 VAC or 110- 300 VAC @ 50% load | 85- 140 VAC or 160- 280 VAC@ 100% load
- Frequency Range : 40 Hz ~ 70 Hz
- Power Factor : ? 0.99 @ nominal voltage (100% load)
Output
- Output Voltage : 100/110/115/120/127 VAC or 200/208/220/230/240 VAC
- AC Voltage Regulation (Batt. Mode) : 1%
- Frequency Range (Synchronized Range) : 47~53 Hz or 57~63 Hz
- Frequency Range (Batt. Mode) : 50 Hz 0.25 Hz or 60Hz 0.3 Hz
- Current Crest Ratio : 3:1 (max.)
- Harmonic Distortion ?3 % THD (Linear Load) ; ? 6 % THD (Non- linear Load)
- Transfer Time : Inverter to Bypass - 4 ms (Typical)
Effiency
- AC Mode : 90%
- Battery Mode : 88%
Battery
- Battery Type : 12 V / 9 Ah
- Numbers : 6
- Typical Recharge Time : 4 hours recover to 90% capacity
- Charging Current (max.) : 1 A
- Charging Voltage : 82.1 VDC 1%
Indicators
- LCD Display : UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Alarm
- Battery Mode : Sounding every 4 seconds
- Low Battery : Sounding every second
- Overload : Sounding twice every second
- Fault : Continuously sounding
Warranty
- 1 Year