2. In the running interface, Long Press ' TM-' key more than 3 seconds, into the stop temperature settings interface, can be modified by TM+ TM-key, to be modified after the parameters, waiting for 6s automatic exit and save; The humidity function is as follows:
1. The automatic identification of work mode:
The system automatically according to the start/stop humidity, identify work mode;
Start humidity > stop humidity, dehumidification mode'D'.
Start humidity < stop humidity, humidification mode 'E'.
2. Dehumidification mode:
When the humidity Start humidity, relay conduction, green led on, dehumidification equipment begin to work;
When the humidity Shop humidity, relay disconnect, green led off, dehumidification equipment stops to work;
3. Humidificationmode:
When the humidity Start humidity, relay conduction, green led on, humidification equipment begin to work;
When the humidity Shop humidity, relay disconnect, green led off, humidification equipment stops to work;
4. Humidificationcorrection function RH (-10.0 ~ 10%):
The system is working for a long time and may be biased, through this function correctly, the actual humidity= measuring humidity + calibration value;
How to set the start/stop humidity:
1. In the running interface, Long Press ' RH+ ' key more than 3 seconds, into the start humidity settings interface, can be modified by RH+ RH- key, to be modified, waiting for 6s automatic exit and save;
2. In the running interface, Long Press ' RH-' key more than 3 seconds, into the stop humidity settings interface, can be modified by RH+ RH- key, to be modified after the parameters, waiting for 6s automatic exit and save;
Package includes:
1 x Module with Sensor