DA2ETH: DA converter with two voltage or current outputs with Ethernet
DA2ETH: DA converter with two voltage or current outputs with Ethernet
DA2ETH: DA converter with two voltage or current outputs with Ethernet

DA2ETH: DA converter with two voltage or current outputs with Ethernet

New
-+
10 available
R8,076.00
Shipping
Standard courier shipping from R30
R30 Standard shipping using one of our trusted couriers applies to most areas in South Africa. Some areas may attract a R30 surcharge. This will be calculated at checkout if applicable.
Check my rate
Free collection from Gardens, Cape Town
The seller allows collection for this item and will be in contact with the full collection address once the order is ready. Ready for collection by Friday, 3 May.
Ready to ship in
The seller has indicated that they will usually have this item ready to ship within 4 business days. Shipping time depends on your delivery address. The most accurate delivery time will be calculated at checkout, but in general, the following shipping times apply:
 
Standard Delivery
Main centres:  1-3 business days
Regional areas: 3-4 business days
Remote areas: 3-5 business days
Buyer Protection How you're covered
Get it now, pay later

Product information

Condition:
New
Location:
South Africa
Product code:
DA2ETH
Bob Shop ID:
608765695

DA2 analog outputs can be used for process regulation and automation or controlling analog inputs (e.g.  electronic thermostats, electronic valves, speed control, dimming of lighting,...).

Princip funkce

Device function principal

Features

  • Two analog outputs (independent settings for current or voltage). Available ranges:
    0 10 V, 0 5 V, 10 V, 5 V, 4 20 mA, 0 20 mA, 0 24 mA
  • Each output galvanically isolated.
  • Output range divided to 10 000 divisions.
  • Active current outputs.
  • Default output value is configurable. An interval can be set after which the output automatically reverts to the default value.
  • 16 bit D/A converter
  • Ethernet communication using Modbus TCP (server or client), SNMP, HTTP GET,
    TCP/UDP (Spinel).
  • Wide power voltage range (8 to 30 V).

Output control options

All settings mentioned below is described in detail in the datasheet that can be downloaded in PDF format.

1) Manual: WEB interface

Manual input using the WEB interface.

Manual input using WEB interface

2) Automatic: Modbus TCP (client mode)

Automated reading from a remote device using ModBus TCP protocol (client mode). DA2 automatically reads ModBus registers from a remote device and sets the output parameters based on that.

Modbus TCP (client)

3) Automatic: AD4ETH input mirroring

Extend analog signals over a great distance using Ethernet (Internet/Ethernet) working in tandem with AD4ETH module. After the settings are stored, DA2ETH starts to read values from AD4ETH periodically and set those values on its outputs, thus states of two analog signals can be transmitted this way.

Input mirroring

4) Automatic: Modbus TCP (server mode)

Changing outputs using Modbus TCP (server mode). A remote client can set output values by writing them into ModBus register in DA2 unit.

5) Automatic: XML

Automated reading from a remote server using XML. Remote server has the data in XML format, DA2 unit reads them periodically and sets output values

XML

6) Automatic: HTTP GET

Set output values using HTTP GET. Remote server calls script in DA2 unit and sends the output values as parameters.

HTTP GET

7) Automatic: SNMP

Using SNMP (Simple Network Management Protocol). A standardized protocol used for network management. DA2 acts as an SNMP agent.

8) Automatic: TCP/UDP

Using TCP communication with Spinel protocol. Available modes are TCP server, TCP client, UDP. This communication option cannot be combined with other options.

Data reading in XML format

All values from the DA2ETH converter can also be obtained in XML format. That is one of the easiest ways to automatically read data from any converter. Example of DA2ETH XML:

1<root>
2    <out id="1" status="0" range="2" value="5.00" divs="5000" />
3    <out id="2" status="0" range="4" value="7.62" divs="2450" />
4    <status location="U Papoucha" />
5</root>

Block diagram

The device is divided into three completely galvanically isolated sections:

  1. Power, processor unit and Ethernet,
  2. output 1,
  3. output 2.
Blokov zapojen

Block diagram DA2ETH

Due to the galvanic isolation, the analog converter can be connected to other systems without damaging the equipment or adversely affecting the systems because of the connection of different voltage potentials via a common ground conductor.

More from this seller

View all
R30 shipping
Bluesky Moonlight & Roses
R305
R30 shipping
Tinsel Toast 80544
R237
R30 shipping
Bluesky Miss Cala Lily (Glass Finish) A102
R305
R30 shipping
Bluesky Cosmic Cornsilk A068
R305
Add to cart

Similar products

R30 shipping
AD4ETH: Ethernet measurement module
R30 shipping
Quido ETH 30/3: 30 inputs, 3 outputs and thermometer
R8,356
R30 shipping
GNOME232: Ethernet to RS232 converter
R30 shipping
Papago 2TH ETH: 2x Temperature, Humidity and Dew Point with Ethernet
R6,748