This item has closed with no items sold
View the relisted Item
View the relisted Item
View other items offered by Diy Select - Cape Town7174

Similar products

R30 shipping
Step Up Down Boost Buck Converter DC-DC Panel Mount Display 5-30V 4A **LOCAL STOCK**
R295
R30 shipping
Step Up Down Boost Buck Converter Charger LM2596 3A (DC-DC) **LOCAL STOCK**
R195
R30 shipping
Step Down Buck Converter Voltage + Current 50V 5A 250W Panel Mount Colour Display **LOCAL STOCK**
R650
R30 shipping
Step Up Down Boost Buck Converter 5A Auto Constant Voltage with Display (DC-DC) **LOCAL STOCK**
R275

Step Up Down Boost Buck Converter DC-DC Panel Mount Display 5-30V 4A **LOCAL STOCK**

New
R295.00
Shipping
Standard courier shipping from R30
R30 Standard shipping using one of our trusted couriers applies to most areas in South Africa. Some areas may attract a R30 surcharge. This will be calculated at checkout if applicable.
Check my rate
Free collection from Vasco Estate, Cape Town
The seller allows collection for this item and will be in contact with the full collection address once the order is ready. Ready for collection by Tuesday, 30 April.
Ready to ship in
The seller has indicated that they will usually have this item ready to ship within 2 business days. Shipping time depends on your delivery address. The most accurate delivery time will be calculated at checkout, but in general, the following shipping times apply:
 
Standard Delivery
Main centres:  1-3 business days
Regional areas: 3-4 business days
Remote areas: 3-5 business days
Buyer Protection How you're covered
Get it now, pay later

Product information

Condition:
New
Location:
South Africa
Product code:
STE525
Bob Shop ID:
610220325

Step Up + Down, Voltage + Current:

 

Specifications:

Model: ZK-4KX
Input Voltage: 5-30V
Output Voltage: 0.5-30V
Output Current: Can work stably at 3A for a long time, and can reach 4A under enhanced heat dissipation
Output Power: Natural heat dissipation 35W, strengthen heat dissipation 50W
Conversion Efficiency: about 88%
Operating Frequency: 180KHZ
Size: 79 x 43mm x 26mm

 

How To Use:

1. Switch display parameters -- in the normal interface, press SW to switch the display below the display screen, and switch the display content between current A power W capacity Ah time h.Long press SW button to switch the uplink display on the display screen and switch the display content between input voltage IN output voltage OUT.


2. Set output voltage -- press U/I button in the normal interface to enter the interface of setting voltage constant current.It can be seen that a certain digit of the output voltage value is flashing. Rotate the encoder left and right to adjust the major and minor.Short press the rotary encoder to choose which bit of output voltage to set.After setting, press U/I button 2 times to return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.


3. Set constant current value (that is, the maximum current value allowed to output by the module) -- press U/I button in the normal interface to enter the setting voltage constant current interface.Then press U/I button and switch to setting constant current value. You can see a bit of the setting constant current value flashing. Rotate the rotary encoder left and right to adjust the major and minor.Short press the rotary encoder to choose which bit to set the constant current value.After setting, press U/I to exit the setting voltage constant current interface and return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.


4. Set the default on/off state of module power-on -- long press U/I in the normal interface to enter the parameter setting interface.You can see that it shows "OPEN OFF" or "OPEN ON". "OPEN OFF" means the output is turned OFF by default when power is ON, and "OPEN ON" means the output is turned ON by default when power is ON.Long press rotate encoder to switch two states.After setting, long press U/I to return to the normal interface.


5. Setting of protection parameters on state and threshold -- long press U/I to enter the parameter setting interface in the normal interface.Press SW until the protection you want appears.LUP -- undervoltage protection threshold;OUP -- overvoltage protection threshold;OCP -- overcurrent protection threshold;OPP -- over power protection threshold;OAP -- ultra-capacity protection threshold;OHP timeout protection threshold;OTP -- overtemperature protection threshold.Short press rotate encoder to select which bit you want to set the protection parameter.Long press the rotary encoder to set the protection parameters on or off (only timeout protection and supercapacity protection can be set to turn on/off, and other protection parameters are turned on by default.).Rotate the encoder left and right to make the parameters bigger and smaller.After setting, long press U/I to return to the normal interface.


6. Calibration voltage and current -- press U/I button to enter the parameter setting interface under normal interface.Press SW until a parameter interface with CAL appears.The calibration input voltage interface with the symbol CAL+IN+V;The calibration output voltage interface with the symbol CAL+OUT+V;The calibration output current interface with the symbol CAL+OUT+A.Rotate the encoder left and right to adjust the size of parameters.After the adjustment is completed, long press the rotary encoder to confirm the adjustment is completed, and the parameter value is no longer flashing.Long press U/I to return to the normal interface.
Note: in order to ensure the accuracy of calibration, calibration voltage -- above 12V can only be started;Calibration current - start calibration only when the current is above 1A.

 

 

Please see all our listings here:
https://www.bidorbuy.co.za/seller/4397469

More from this seller

View all
Temperature Controller Thermostat W1209 12V DC Red **LOCAL STOCK**
R70
R30 shipping
PH Meter Tester Digital + Buffer Powders **LOCAL STOCK**
R180
Connector Dupont Housing 1 Pin **LOCAL STOCK**
R0.15
Micro Limit Switch Button for Click Mouse **LOCAL STOCK**
R6