Main centres: | 1-3 business days |
Regional areas: | 3-4 business days |
Remote areas: | 3-5 business days |
Detail | Specifications | Tipical | Unit |
Discharge | Continuous Discharging Current | 35(Max) | A |
Instantaneous Discharge Current | 100 | A | |
Charge | Charging Voltage | 54.6 | V |
Charging Current | 8(Max) | A | |
Overcharge Protect | Over-charge Detect | 4.28±0.05 | V |
Protect Delay | 100 | mS | |
Over-charge release | 4.08±0.05 | V | |
Balance | Detect Voltage | 4.2±0.025 | V |
Release Voltage | 4.2±0.05 | V | |
Balance Current | 60±5 | mA | |
Over-discharge Protect | Over-discharge Detect | 2.55±0.08 | V |
Over-discharge Detect delay | 50 | mS | |
Release Voltage | 3.0±0.1 | V | |
Over-current Protect | Detect Voltage | 150 | mV |
Detect Delay | 15 | mS | |
Current Detect | 120±0.5 | A | |
Release Condition | Cut Load | ||
Short-circuit Protect | Protect Condition | External load short circuit | |
Detect Delay | 200 | uS | |
Release Condition | Cut Load | ||
Temperature Protect | Temperature Protect | / | a |
Resistance | Inner | a15 | m |
Self-Consumption | Working Current | a50 | uA |
Sleep Current (when Over-discharge) | a10 | uA | |
Working Temperature | Range | -30/+80 | a |