Main centres: | 1-3 business days |
Regional areas: | 3-4 business days |
Remote areas: | 3-5 business days |
Features:
The user can select one of the following 20 functions by pressing the button and display, and can set and save the function parameters, and also view the parameters of the current function. The time parameter setting is adjustable by 0.1 second at , and the is better than 0.01 second. Instructions for setting up can be obtained from your dealer.
Load capacity: Normally open port load capacity: DC 0-30V/10A, AC 0-250V/10A
Normally closed port load capacity: DC 0-28V/10A, AC 0-125V/10A
Tips:
Function 1-8 is self-starting when it is powered on. Function 9-18 requires a high-level pulse signal (high-level duration is not shorter than 20ms, the same below) triggers the start, and function 19-20 requires a continuous high level.
Module interface:
Module control terminal:
1. +: DC power supply positive (24V modules)
2. DC-: DC power supply negative
3. CH1: Input detection interface 1, active high
4. CH2: Input detection interface 2, active high
output:
1. NO1: The normally open interface 1, the is suspended before the suction, and it is short-circuited with COM1 after the suction.