ZFX-W1605 Intelligent Humidity Controller with Digital DisplayHumidity Control Sw... (VOLTAGE: 220V)

New
-+
12 available
R411.00
Shipping
Standard courier shipping from R30
R30 Standard shipping using one of our trusted couriers applies to most areas in South Africa. Some areas may attract a R30 surcharge. This will be calculated at checkout if applicable.
Check my rate
Ready to ship in
The seller has indicated that they will usually have this item ready to ship within 15 business days. Shipping time depends on your delivery address. The most accurate delivery time will be calculated at checkout, but in general, the following shipping times apply:
 
Standard Delivery
Main centres:  1-3 business days
Regional areas: 3-4 business days
Remote areas: 3-5 business days
Returns
Replacement 7 Days
Replacement Guarantee: 7 Days: We stand by this guarantee
Get it now, pay later
Seller
Buyer Protection

Product details

Condition
New
Location
International
Bob Shop ID
615105823

SELECTED OPTION:
VOLTAGE: 220V

.size_table_start table,.size_table_start table tr td { border:2px solid #ddd;}.size_table_start table { width: 100%; min-height: 25px; line-height: 25px; text-align: center; border-collapse: collapse;}.size_table_start,.size_table_end {clear:both;}
Specifications:
Product model: ZFX-W1605 Humidity measurement range: 1% RH ~ 99% RH Humidity measurement accuracy: 1% RH Resolution: 0.1 Humidity control range: 00% RH ~ 99% RH Humidity control accuracy: 1% RH Transmission line: L = 1m Power supply voltage: DC 12V / DC 24-60V / AC 220V Applicable environment: -25 ~ 55 ????, humidity 90% RH (no condensation) Output type: direct output Diameter: 86mm
Setting:
1. In the setting mode, long press the SET button for 5 seconds, P0 will be displayed, and short press the SET button to switch the H / C (H is humidification, C is dehumidification) 2. Set the stop humidity, press the SET button once, the screen flashes, and press the up and down keys to directly set the required humidity 3. Press and hold the SET button for 5 seconds to display P0, press the up and down buttons to switch to P1, and then press the SET button once again to set the return difference (press the up and down buttons to adjust) If the humidification mode wants to be set between 35 and 37, then the stop humidity is set to 37, then the hysteresis must be set to 2 4. Indicator light: SET light is on, indicating that the parameter is being set: OUT indicator flashes to indicate the start delay, and constant light indicates the output 5. Nixie tube: display LLL as sensor abnormality: display HHH as sensor causing short circuit or exceeding measurement range, when humidity is blinking, it is in the setting or alarm state.
ParameterFeaturesRangeDefaults
P0Operating?modeHumidification?/?DehumidificationH
P1Backlash?setting1~20%RH2
P2Humidity?correct-20~20%RH

More from this seller

View all
R30 shipping
2pcs Red 1157 P21/5w Bay15d Super Bright Light Stop Bulbs
R304
R30 shipping
Drillpro 8mm Shank Template Trim Hinge Mortising Router Bit Bearing Straight End Mill ... (SIZE: 3#)
R377
R30 shipping
Car OBD to Cigarette Lighter Female Seat Driving Recorder Power Cord 60cm
R248
R30 shipping
10 PCS Camera Lens Cover for Nokia C5 Endi (Blue)
R258
Add to cart

Similar products

R30 shipping
Deek-Robot W-1211 AC110-220V Digital Display Temperature Humidity Controller for Incubator Cool Heat
R473
R30 shipping
W3003 12V/24V/220V Microcomputer Digital Display Intelligent Temperature Controlle... (VOLTAGE: 24V)
R401
R30 shipping
XH-W3001 Microcomputer Digital Temperature Controller Thermostat Temperature Co... (VOLTAGE: AC220V)
R390
R30 shipping
ZFX-W1015 12V/24V/220V Digital Display Multi-function Intermittent Cycle Timer (VOLTAGE: 12V)
R455